TOPSFLO diaphragm pump applied to fluorescence immunoassay analyzer
2024-06-28

Industry Overview

With the rapid development of biotechnology and medical diagnostic technology, fluorescence immunoassay technology has become an indispensable part of modern medical diagnosis. Fluorescence immunoassay technology combines the high specificity of immune reactions and the high sensitivity of fluorescence technology, enabling rapid and accurate quantitative analysis of the content of various analytes in biological samples such as human blood and urine. In this context, the market demand for fluorescence immunoassay analyzers continues to grow, and the requirements for equipment performance and supporting equipment are also increasing.

fluorescence immunoassay analyzer pump


TOPSFLO diaphragm pump solution

The liquid processing system is a crucial component in the operation of the fluorescence immunoassay analyzer. The liquid treatment system not only needs to ensure accurate mixing and transportation of samples, reagents, and buffer solutions, but also needs to provide a stable temperature controlled environment for the mixture during the reaction process, and discharge used consumables into the waste liquid without residue after analysis. To meet these needs, we provide solutions for diaphragm pump products.

Performance advantages:

Diaphragm pumps have significant advantages in the field of liquid treatment due to their unique structure and working principle. Firstly, the diaphragm pump has self suction capability, which can complete the suction and discharge of liquids without the need for external power sources. Secondly, the diaphragm pump uses a flexible diaphragm as the power transmission, minimizing the leakage of pollution sources to the greatest extent possible. In addition, TOPSFLO diaphragm pumps also have the following advantages:

Low pulse, stable flow rate

The design of TOPSFLO diaphragm pump is advanced and can provide stable and uniform flow output. During the needle washing and waste disposal process, this stable flow ensures that the washing solution can be evenly distributed, thoroughly removing residual samples and avoiding the risk of cross contamination. This is crucial for laboratories and medical applications.

Low noise operation: creating a quiet working environment

The TOPSFLO diaphragm pump generates extremely low noise during operation and will not cause interference to the laboratory or working environment. This low noise characteristic helps operators maintain focus and improve work efficiency.

Multiple membranes available: adaptable to various media

TOPSFLO diaphragm pumps offer a variety of diaphragm options to meet the needs of different detergent components. This means that you can choose the appropriate diaphragm according to the specific application scenario, ensuring that the pump can maintain optimal performance and durability when handling different media.


Long life design: reducing maintenance costs


After rigorous testing and durable design, TOPSFLO diaphragm pumps have an ultra long service life. This greatly reduces replacement frequency and maintenance costs, providing customers with an economically efficient solution. After long-term use, you will find that this pump not only has excellent performance, but also has a very high cost performance ratio.

Product recommendation:

For the specific needs of fluorescence immunoassay analyzers, we recommend using TOPSFLO TF30 series diaphragm pumps


Model

Rated Voltage
(VDC)

Current (A) 

Max Head (Bar)

Max Vacuum (Kpa)

Max Flow(L/min)

TF30A-A01-12-W101

12

0.4

≥1

60

1

TF30A-A01-12-W1006

12

0.4

≥1

70

0.6



Summary

With the continuous development of fluorescence immunoassay technology, the requirements for the performance and supporting equipment of fluorescence immunoassay analyzers are also increasing. TOPSFLO's solution based on diaphragm pump products can effectively meet the various needs of fluorescence immunoassay analyzers in liquid processing, providing strong support for the development of medical diagnosis.


Pre: Visit TOPSFLO with KTM and discover the secret of the pump's quality leadership

Next:Application of TOPSFLO Diaphragm Vacuum Pump in Negative Pressure Therapy for Trauma